Skip to Content
  • Delivery in 4–10 working days across Saudi Arabia
  • A tax invoice with every order
  • Technical support before and after you buy

Sizing a Delta 48 V Power Supply for PoE Switches and Cameras

A practical way to size a 48 V supply for PoE switches and cameras, with worked examples on the 240 W Delta DRL-48V240W1EN and common mistakes.

Table of contents

No titles in the blog post

A power supply that is too small shuts down the switch and cameras at the worst moment, and one that is far too big adds cost for no benefit. This guide explains a practical way to size the power you need, with examples on the 240 W Delta DRL-48V240W1EN.

1. Add up the devices

Start with the maximum consumption of every device the switch powers over PoE, as given in its specification, not the average. A camera, for example, draws more at night with its infrared on, and a PTZ camera draws more while it moves.

2. Add the switch itself

The switch has its own consumption on top of what it delivers over PoE, usually given in its specification. Add any other equipment the same supply feeds in the cabinet.

3. Add a margin

Add a 20 to 30% margin above the total so the supply runs well below its limit, stays cooler and absorbs temporary peaks and future additions. High temperatures inside cabinets can also reduce the power a supply can deliver, so check the derating curve in the manufacturer's specification.

4. Examples on 240 W

The figures below are assumptions for illustration, so use your own devices' numbers. The margin in the table is 25%.

ScenarioLoadWith marginWithin 240 W?
8 cameras at 12 W and a 20 W switch116 W145 WYes
12 cameras at 12 W and a 25 W switch169 WAbout 211 WYes
4 PTZ cameras at 30 W, 8 cameras at 12 W and a 25 W switch241 WAbout 301 WNo, it needs a bigger supply or two supplies

5. Working out the current

To check by current instead of power, divide the power by the voltage: 240 W ÷ 48 V = 5 A, which is the rated current on the supply page. A 145 W load, for example, is about 3 A on the 48 V output.

6. Common mistakes

  • Relying on the switch PoE budget alone and forgetting the switch's own consumption.
  • Counting cameras at their daytime average rather than their night-time maximum.
  • Ignoring the effect of cabinet heat on the supply rating.
  • Leaving no room for extra cameras later.

Also check that the switch input range includes 48 V and that the switch PoE budget covers the devices; a strong supply does not make up for a switch with a small budget.

For the supply specification, see our guide to the DRL-48V240W1EN.

To set up the cabinet, see our guide to setting up a network cabinet.

The product in this guide

Frequently asked questions

Should I size the supply to the switch PoE budget?

Size it to the actual maximum load plus the switch consumption and a margin; if you will use the switch's full budget in future, size to that instead.

What if the load exceeds 240 W?

Split the devices across two supplies and two switches, or choose a higher-rated supply; Rasid's team can help with the design.

Is the margin really necessary?

Yes, it protects against temporary peaks, keeps the supply cooler and leaves room to grow.

Need help choosing the right Delta solution?

Rasid's team in Riyadh helps you choose the right equipment for your site and handles supply, installation and programming for businesses, hotels and homes in Saudi Arabia. Message us on WhatsApp +966559790746 or request a solution for your project.