Heat is the biggest enemy of network equipment: a switch that runs hot fails sooner, and the hard drive in a recorder wears out faster. With the Saudi summer, cabinet cooling becomes a core part of the design. This guide explains the ventilation Avayo cabinets provide and how to complete it.
1. Included fans
- Wall cabinets 4U to 18U: one heavy-duty, quiet roof fan.
- 18U floor cabinets: four quiet roof fans.
- Floor cabinets 22U to 42U: fans are not listed among the accessories, so order them according to the heat load.
Roof fans draw out the hot air that rises to the top of the cabinet, so keep anything that would block the openings off the top.
2. Glass or mesh door?
A glass door protects equipment from tampering and lets you see the status lights without opening the cabinet, but it reduces airflow at the front. A mesh door lets air pass freely and suits equipment that draws air in at the front and pushes it out at the back. In Avayo's 800 mm-wide 42U models you can choose the GP, with a glass front door and a mesh rear door, or the 2P, with two mesh doors.
3. Airflow inside the cabinet
- Most switches and servers draw air in at the front and exhaust it at the back, so mount them all facing the same way.
- Close empty units with blanking panels so hot air does not loop back to the front.
- Dress the cables behind the equipment and do not let them block the exhausts.
- Leave a free unit above the hottest devices if space allows.
4. Room temperature matters more than the fan
A fan moves air but does not cool it, so in a hot room hot air goes into the equipment. ASHRAE recommends an inlet air temperature of 18 to 27 °C for IT equipment. Place the cabinet in an air-conditioned room, and do not install it on a rooftop, in an electrical room or in an unconditioned store, where summer temperatures run much higher.
5. Dust and protection
Avayo cabinets are rated IP20, which keeps out objects larger than 12.5 mm but gives no water protection, so they are for indoor use. On dusty sites, clean the fan openings and mesh doors regularly so the airflow does not clog.
Monitor the temperature: many switches and servers show their internal temperature in the management interface, so make checking it part of routine maintenance.
For installation steps and cable management, see our guide to installing a network cabinet.
Products mentioned in this guide
- Avayo AVE-W04S-6035B – 4U wall with roof fan
- Avayo AVE-W18SS-6060B – 18U wall with fan and PDU
- Avayo AVE-F1866-09B – 18U floor with four fans
- Avayo AVE-F1861-09B – 18U floor, 1,000 mm deep, four fans
- Avayo AVE-F4281-20B-GP – 42U, glass front and mesh rear doors
- Avayo AVE-F4281-20B-2P – 42U with two mesh doors
- Avayo AVE-F4261-20B – 42U floor, 1,000 mm deep
Frequently asked questions
Is one fan enough for a wall cabinet?
It is usually enough for a cabinet of switches and patch panels in an air-conditioned room; hotter equipment needs a cool room and space to breathe.
Which doors are best for servers?
Mesh doors, as on the 2P model, because they let air flow from front to back.
Can the cabinet go in a room without air conditioning?
It is not recommended in Saudi Arabia, because summer room temperatures can exceed what the equipment tolerates.
Need help choosing the right Avayo solution?
Rasid's team in Riyadh helps you choose the right equipment for your site and handles supply, installation and programming for businesses, hotels and homes in Saudi Arabia. Message us on WhatsApp +966559790746 or request a solution for your project.