A door access system is a chain of devices: a reader that identifies the person, a panel or terminal that decides, a lock that opens and a button to exit. ZKTeco offers every link in this chain. This guide explains the role of each part and how to choose it.

1. Standalone unit or control panel?

For a single door, a standalone unit that identifies and opens the lock itself is enough, such as the X8S with 500 fingerprints, 500 cards and a touch keypad, or the outdoor IP65 TF1700, which works without a PC and holds 3,000 fingerprints and 10,000 cards. Buildings with several doors use a central control panel that the readers connect to.

2. Ready-to-install inBio panels

The inBio160 Pro, inBio260, inBio260 Pro, inBio460 and inBio460 Pro come in the Package B kit with the panel, a metal box and a power supply, ready for wall installation. The Rasid team picks the right panel for the number of doors and readers in your project.

3. Readers

  • FR1200: a fingerprint and card reader that works with the panel over RS485 or OSDP, verifies fingerprints in under 0.3 s, is IP65-rated and mounts on a wall or door frame.
  • KR500E, KR501E and KR502E: 125 kHz card readers with 26-bit Wiegand output, reading up to 10 cm in 200 ms or less, rated IP65 or IP64.

4. Exit buttons and helpers

An exit button opens the door from inside without a card: the EX-802 is flame-retardant plastic rated for 100,000 presses, the EX-800B is aluminium and the EX-801B stainless steel, while the TLEB101 is a touchless infrared button sensing from 2 to 10 cm. To drive a lock or external device there is the RM01 relay module.

5. Card types

125 kHz cards such as the TK1400 are read-only with a unique ID and work with KR readers. 13.56 MHz Mifare cards such as the 1K MF1 and 4K MF4 are used in systems that support them, such as hotel locks, and have a printable surface.

To choose the right lock for the door, see our guide to ZKTeco magnetic locks.

Examples by case

CaseChoiceExample
One office doorStandalone fingerprint unitZKTeco X8S
Outdoor doorIP65 unit working without a PCZKTeco TF1700
Several doorsPanel with box and power supplyZKTeco inBio460 Pro
Fingerprint reader on the panelRS485 and OSDPZKTeco FR1200
Outdoor card reader125 kHz, IP65ZKTeco KR500E
Touchless exitInfrared buttonZKTeco TLEB101

Products mentioned in this guide

Frequently asked questions

Wiegand, RS485 or OSDP?

All three connect a reader to the panel: Wiegand is common and simple, RS485 links several devices on one cable, and OSDP is a newer protocol over RS485 supported by the FR1200 reader and the G4 Pro.

Can I keep the staff cards I already have?

If they are 125 kHz EM cards they work with KR readers; Mifare cards need a reader that supports 13.56 MHz.

Where does the control panel go?

Inside the building in a secure place near the doors or in the equipment room; the Package B kit comes with a metal box and power supply for this.

Need help choosing the right ZKTeco solution?

Rasid's team in Riyadh helps you choose the right equipment for your site and handles supply, installation and programming for businesses, hotels and homes in Saudi Arabia. Message us on WhatsApp +966559790746 or request a solution for your project.