The wired network is the foundation that computers, phones, cameras and Wi-Fi access points rely on in any office, and most of its problems start with random cabling that nobody can trace. In this guide the Rasid team explains how structured cabling is delivered step by step: from counting points and planning routes to labelling, testing and handover.
1. What structured cabling means
Structured cabling means every network point has a fixed, documented path from the user's desk to a patch panel inside the network rack, instead of cables running directly from the switch to each device. The system usually consists of horizontal cabling from the rack to the wall outlets, backbone cabling between floors or rooms, the telecom room or rack, and short patch cords at the desk and in the rack. This order makes every move, addition or diagnosis quick and clear.
2. Counting outlets and planning routes
We start with a site visit and the office layout, and count the points each desk needs: computer, phone and printer, then ceiling points for Wi-Fi access points, cameras, attendance devices and meeting room screens. We add spare points, because adding a point after the finishing work is much harder and more expensive. Then we place the rack as close to the centre of the space as possible, so no route exceeds the allowed distance.
3. Choosing the cable: Cat6 or Cat6A?
The standard limits the full channel to 100 m, of which 90 m is the fixed run and the rest is patch cords. Cat6 covers most offices at gigabit speed and supports 10 Gbps over shorter distances. Cat6A supports 10 Gbps over the full distance, a good choice for new buildings and for modern Wi-Fi access points. Near sources of electrical noise we prefer shielded cable with proper earthing, and inside offices we choose a low-smoke jacket.
Browse the network cables we supply.
4. Routes and protection
Cables run inside cable trays or suitable conduits, kept away from power cables or crossing them at right angles, because long parallel runs next to power cause interference. We respect the allowed bend radius, never pull cable ties tight enough to crush the cable, and never leave cable lying on a false ceiling without support. These are small details, but they decide whether the point keeps working at full speed for years.
For cameras and PoE rules, see our CCTV cabling and PoE guide.
5. Termination in the rack
Every cable terminates on patch panels in a fixed order, and from there short, tidy patch cords connect to the switch. We use cable managers between panels and switches, leave a neat service loop behind the rack, and use different patch cord colours per device type, such as phones, cameras or Wi-Fi access points, so they are easy to tell apart.
Choosing and installing the rack is covered in our network rack installation guide.
6. Labelling and documentation
- A clear number for every point, the same code on the wall outlet and on the patch panel.
- A drawing showing the location, number and route of every point as actually built.
- A table linking each switch port to its point and the connected device.
- Photos of the rack after completion, useful for any later maintenance.
7. Testing and handover
Before handover we test every point with a suitable tester, checking the wire map and that there are no opens, swapped pairs or excess length, then hand you the results report together with the drawings and the port table. Any point that fails is re-terminated before the work is accepted.
The difference between test types is explained in our network cable testing guide.
Frequently asked questions
Should I choose Cat6 or Cat6A for a new office?
Cat6 is enough for most offices today. If the building is new and you plan modern Wi-Fi access points or higher speeds later, Cat6A is the better investment, because replacing cables after finishing is difficult.
How many network points does each desk need?
It depends on the work, but we usually plan at least two points per employee, plus points for printers, screens and Wi-Fi access points, and spares for growth.
Need installation or maintenance?
Rasid's team works out of Riyadh and travels for supply, installation, programming and maintenance in Riyadh, Dammam, Khobar, Jeddah and across the Eastern Province, with annual maintenance contracts for businesses and homes. Message us on WhatsApp +966559790746 or request a solution for your project.